Xscale

Verified scales

Please select your scale manufacturer

G & G Gmbh

Tare Print
27 116 27 112
Model Interval Sent buffer Received buffer Baud Databit Stopbit Parity Cable
G & G  - Moldel  DJ 300 DJ 300 500 16 16 9600 8 1 None Type 1
Jadever Scale CO., LTD

Tare Print
84 82
Model Interval Sent buffer Received buffer Baud Databit Stopbit Parity Cable
Jadever Scale Co, Model Sky-W Sky-W 1000 20 20 9600 8 1 None Type 4
Required settings for Sky-W
1) Menu PEri (external device)
• Need to be set to PC
2) Menu bAUd (RS-232-Serial Transmission Rate)
• Check the given value and note it (9600 default)
3) Menu Prtn (Print mode)
• Set to Key (if print value is 82 – more accurate but continuos beep on scale)
• Set to stable (if print value is empty in Xscale – less accurate)

Kern & Sohn GmbH

Tare Print
116 119
Model Interval Sent buffer Received buffer Baud Databit Stopbit Parity Cable
Kern & Sohn - Moldel Kern PCB Kern PCB 1000 18 18 9600 8 1 None Type 2
Mettler Toledo

Tare Print
90 0 0 0 0 0 0 0 0 0 0 0 0 0 13 10 83 0 0 0 0 0 0 0 0 0 0 0 0 0 13 10
Model Interval Sent buffer Received buffer Baud Databit Stopbit Parity Cable
Mettler toledo PB3002-S05 PB3002-S05 1000 15 15 9600 8 1 None Type 2
Sartorius

Tare Print
Model Interval Sent buffer Received buffer Baud Databit Stopbit Parity Cable
Mettler toledo PB3002-S05 1413 MP8-1 1200 7 1 Odd Type 5 and 6
U.S. Solid

Tare Print
Model Interval Sent buffer Received buffer Baud Databit Stopbit Parity Cable
US-Solid-Model-USS-DBS46-1 USS-DBS46-1 1000 16 16 9600 8 1 None Type 4

RS232 Cable connection alternatives

DSub 9 plug on Scale

A) Direct RS232 cable connection to a computer with a DSub 9 plug on cable.

B) RS232 Cable connection to a computer with a DSub 9 plug on cable, plus a DSub 9 gender changer adapter.

C) RS232 Cable connection to a computer with a DSub 9 plug on cable, plus a DSub 9 / USB adapter.

D) Direct RS232 cable connection to a computer with an USB plug on cable.

 

DB 25 plug on Scale

A) Direct RS232 cable connection to a computer with a DB 25 plug on cable.

B) RS232 Cable connection to computer with a DB 25 plug on cable, plus a DB 25 / DSub 9 adapter .

C) Direct RS232 cable connection to a computer with a DSub 9 plug on cable.

Cables types

These given cable types where tested and worked at our laboratory. However, other type of cable might work as well.

Depending on the computer you are using you might need to use a RS232 to USB Converter. The given parameters are suggestions only.

Cable type 1

Scale (1) Computer
1 2
2 3
3 4
4 5
5 1
6 Not used
7 7
8 8
9 6


(1) Male DSub 9 plug on cable,
female plug on scale

Cable type 2

Scale (1) Computer
1 5
2 4
3 3
4 2
5 1
6 9
7 8
8 7
9 6


(1) Male DSub 9 plug on cable,
female plug on scale

Cable type 3

Scale (1) Computer
1 Not used
2 4
3 3
4 Not used
5 1
6 Not used
7 Not used
8 Not used
9 Not used


(1) Male DSub 9 plug on cable,
female plug on scale

Cable type 4

Scale (1) Computer
1 Not used
2 3
3 2
4 Not used
5 5
6 Not used
7 Not used
8 Not used
9 Not used


(1) Female DSub 9 plug on cable,
male plug on scale

Cable type 5

25 pol to 25 pol

Scale (1) Computer (2)
2 3
3 2
5 20
7 7
20 5
20 6


(1) Male DB 25 plug on cable,
female plug on scale
(2) DB 25 plug to computer

Cable type 6

25 pol to 9 pol

Scale (1) Computer (2)
3 3
5 4
2 2
20 8
20 6
7 5


(1) Male DB 25 plug on cable,
female plug on scale
(2) DSub 9 plug to computer

Scale not found?
Please, give us some details.
We will try to find the missing information for you.