Xscale
Verified scalesPlease select your scale manufacturer
G & G Gmbh
| Tare | |
|---|---|
| 27 116 | 27 112 |
| Model | Interval | Sent buffer | Received buffer | Baud | Databit | Stopbit | Parity | Cable | |
|---|---|---|---|---|---|---|---|---|---|
![]() |
DJ 300 | 500 | 16 | 16 | 9600 | 8 | 1 | None | Type 1 |
Jadever Scale CO., LTD
| Tare | |
|---|---|
| 84 | 82 |
| Model | Interval | Sent buffer | Received buffer | Baud | Databit | Stopbit | Parity | Cable | |
|---|---|---|---|---|---|---|---|---|---|
![]() |
Sky-W | 1000 | 20 | 20 | 9600 | 8 | 1 | None | Type 4 |
| Required settings for Sky-W | |
|---|---|
| 1) Menu PEri (external device) • Need to be set to PC 2) Menu bAUd (RS-232-Serial Transmission Rate) • Check the given value and note it (9600 default) 3) Menu Prtn (Print mode) • Set to Key (if print value is 82 – more accurate but continuos beep on scale) • Set to stable (if print value is empty in Xscale – less accurate) |
Kern & Sohn GmbH
| Tare | |
|---|---|
| 116 | 119 |
| Model | Interval | Sent buffer | Received buffer | Baud | Databit | Stopbit | Parity | Cable | |
|---|---|---|---|---|---|---|---|---|---|
![]() |
Kern PCB | 1000 | 18 | 18 | 9600 | 8 | 1 | None | Type 2 |
Mettler Toledo
| Tare | |
|---|---|
| 90 0 0 0 0 0 0 0 0 0 0 0 0 0 13 10 | 83 0 0 0 0 0 0 0 0 0 0 0 0 0 13 10 |
| Model | Interval | Sent buffer | Received buffer | Baud | Databit | Stopbit | Parity | Cable | |
|---|---|---|---|---|---|---|---|---|---|
![]() |
PB3002-S05 | 1000 | 15 | 15 | 9600 | 8 | 1 | None | Type 2 |
Sartorius
| Tare | |
|---|---|
| – | – |
| Model | Interval | Sent buffer | Received buffer | Baud | Databit | Stopbit | Parity | Cable | |
|---|---|---|---|---|---|---|---|---|---|
![]() |
1413 MP8-1 | – | – | – | 1200 | 7 | 1 | Odd | Type 5 and 6 |
U.S. Solid
| Tare | |
|---|---|
| – | – |
| Model | Interval | Sent buffer | Received buffer | Baud | Databit | Stopbit | Parity | Cable | |
|---|---|---|---|---|---|---|---|---|---|
![]() |
USS-DBS46-1 | 1000 | 16 | 16 | 9600 | 8 | 1 | None | Type 4 |
RS232 Cable connection alternatives
A) Direct RS232 cable connection to a computer with a DSub 9 plug on cable.
B) RS232 Cable connection to a computer with a DSub 9 plug on cable, plus a DSub 9 gender changer adapter.
C) RS232 Cable connection to a computer with a DSub 9 plug on cable, plus a DSub 9 / USB adapter.
D) Direct RS232 cable connection to a computer with an USB plug on cable.
A) Direct RS232 cable connection to a computer with a DB 25 plug on cable.
B) RS232 Cable connection to computer with a DB 25 plug on cable, plus a DB 25 / DSub 9 adapter .
C) Direct RS232 cable connection to a computer with a DSub 9 plug on cable.
Cables types
These given cable types where tested and worked at our laboratory. However, other type of cable might work as well.
Depending on the computer you are using you might need to use a RS232 to USB Converter. The given parameters are suggestions only.
| Scale (1) | Computer |
|---|---|
| 1 | 2 |
| 2 | 3 |
| 3 | 4 |
| 4 | 5 |
| 5 | 1 |
| 6 | Not used |
| 7 | 7 |
| 8 | 8 |
| 9 | 6 |
(1) Male DSub 9 plug on cable,
female plug on scale
| Scale (1) | Computer |
|---|---|
| 1 | 5 |
| 2 | 4 |
| 3 | 3 |
| 4 | 2 |
| 5 | 1 |
| 6 | 9 |
| 7 | 8 |
| 8 | 7 |
| 9 | 6 |
(1) Male DSub 9 plug on cable,
female plug on scale
| Scale (1) | Computer |
|---|---|
| 1 | Not used |
| 2 | 4 |
| 3 | 3 |
| 4 | Not used |
| 5 | 1 |
| 6 | Not used |
| 7 | Not used |
| 8 | Not used |
| 9 | Not used |
(1) Male DSub 9 plug on cable,
female plug on scale
| Scale (1) | Computer |
|---|---|
| 1 | Not used |
| 2 | 3 |
| 3 | 2 |
| 4 | Not used |
| 5 | 5 |
| 6 | Not used |
| 7 | Not used |
| 8 | Not used |
| 9 | Not used |
(1) Female DSub 9 plug on cable,
male plug on scale
| Scale (1) | Computer (2) |
|---|---|
| 2 | 3 |
| 3 | 2 |
| 5 | 20 |
| 7 | 7 |
| 20 | 5 |
| 20 | 6 |
(1) Male DB 25 plug on cable,
female plug on scale
(2) DB 25 plug to computer
| Scale (1) | Computer (2) |
|---|---|
| 3 | 3 |
| 5 | 4 |
| 2 | 2 |
| 20 | 8 |
| 20 | 6 |
| 7 | 5 |
(1) Male DB 25 plug on cable,
female plug on scale
(2) DSub 9 plug to computer
Scale not found?
Please, give us some details.
We will try to find the missing information for you.





